PowerGridSourceSwitchgear, transformers, breakers, metering devices, and power distribution components for global buyers.
Medium Voltage Switchgear/LV Cubicle Switch Gear Panels Electrical Equipment Supplies - Switchgear a
Medium Voltage Switchgear

Medium Voltage Switchgear/LV Cubicle Switch Gear | RFQ Sourcing Details

Medium Voltage Switchgear · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryMedium Voltage Switchgear
Unitset
typeIP4X for housing No Item Unit Parameter 1 Rated
powerfrequency withstand voltage(wet/dry) kV 70/95 7 Lightning impulse withstand
VoltageSwitchgear/LV cubicle switch gear panels electrical equipment supplies A c metal closed
Certificateand Services 1.Pre sale service a. make technical solution b. send quotation, technical data sheet and drawing c. prepare
SpecificationNo Item Unit Parameter 1 Rated
CategoryMedium Voltage Switchgear
AvailabilityInquiry required
Updated2026-06-11

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Medium Voltage Switchgear. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

Medium Voltage Switchgear/LV cubicle switch gear panels electrical equipment supplies A c metal closed type shift switch cabinet is a three-phase ac 50HZ indoor device metal closed switch equ ipment.Is used in power plants, substation system rated voltage 35kV, rated maximum current 2000A maximum voltage no more than 40.5kV single bus or single bus sectionalized sets of distribution equipment.

This switch device meets the requirements of DL/ t404-91, IEC298, GB3906 and other standards, and has the functions of preventing wrong operation of circuit breaker, pushing and pulling handcart with load, grounding line, power transmission with grounding line and accidental charging interval (referred to as "five precautions") Sw itchgear Structure The Specification No Item Unit Parameter 1 Rated voltage kV 7.2kV, 12kV, 17.5kV, 24kV 2 Ratec frequency Hz 50/60 3 Rated current A 630, 1250, 1600, 2000, 2500, 3150, 4000 4 Branch busbar rated current A 630, 1250, 1600, 2000, 2500, 3150, 4000 5 Main busbar rated current A 630, 1250, 1600, 2000, 2500, 3150, 4000 6 1 min power frequency withstand voltage(wet/dry) kV 38/48, 50/60/60/65 7 Lightning impulse withstand voltage kV 75, 95/125 8 Rated short circuit breaking current(peak) kA 40/50/63/80/100 9 Short time withstand current(4s) kA 20/25/31.5/40 10 Protection type IP4X for housing No Item Unit Parameter 1 Rated voltage kV 36kV, 40.5kV 2 Ratec frequency Hz 50/60 3 Rated current A 630, 1250, 1600, 2000, 2500, 3150, 4000 4 Branch busbar rated current A 630, 1250, 1600, 2000, 2500, 3150, 4000 5 Main busbar rated current A 630, 1250, 1600, 2000, 2500, 3150, 4000 6 1 min power frequency withstand voltage(wet/dry) kV 70/95 7 Lightning impulse withstand voltage kV 170/185 8 Rated short circuit breaking current(peak) kA 20/25/31.5/40 9 Short time withstand current(4s) kA 40/50/63/100 10 Protection type IP4X for housing Our Workshop Note:1.All products will be tested before delivery.

2.All products can be customized. Conditions of Use 1.The maximum ambient air temperature shall not exceed 40°C, and the minimum shall not below -25°C;2.The altitude shall not exceed 1000m.

If special customized transformers and low-voltage components are used, the altitude can reach 4,000m;3.The vertical inclination is no more than 5°, and no violent vibration and impact;4.The air humidity is not more than 90% (25°C);5.No gas and conductive dust that will seriously affect the insulation of transformer,no explosion hazard and corrosion of electrical components;6.Outdoor wind speed shall not exceed 35m/s;7.If service conditions beyond the above, specially customized product is available.

.

Medium | Applications and Buyer Notes

Medium is organized as a sourcing-ready Medium Voltage Switchgear reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Medium Voltage SwitchgearBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
type
IP4X for housing No Item Unit Parameter 1 RatedBased on visible page data; confirm exact value in the RFQ.
power
frequency withstand voltage(wet/dry) kV 70/95 7 Lightning impulse withstandBased on visible page data; confirm exact value in the RFQ.
Voltage
Switchgear/LV cubicle switch gear panels electrical equipment supplies A c metalBased on visible page data; confirm exact value in the RFQ.
Certificate
and Services 1.Pre sale service a. make technical solution b. send quotation, teBased on visible page data; confirm exact value in the RFQ.
Specification
No Item Unit Parameter 1 RatedBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryMedium Voltage Switchgear
Unitset
typeIP4X for housing No Item Unit Parameter 1 Rated
powerfrequency withstand voltage(wet/dry) kV 70/95 7 Lightning impulse withstand
VoltageSwitchgear/LV cubicle switch gear panels electrical equipment supplies A c metal closed
Certificateand Services 1.Pre sale service a. make technical solution b. send quotation, technical data sheet and drawing c. prepare
SpecificationNo Item Unit Parameter 1 Rated

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

PowerGridSource related sourcing paths

PowerGridSource procurement phrases

PowerGridSource related product samples

Supplier profile

PowerGridSource Imported Supplier Pool
主营:Medium Voltage Switchgear

View full profile >